Product Details:

  • Output Stable and Consistent Gas Flow
  • Condition New
  • Fuel Consumption As per burner capacity
  • Capacity Suitable up to 5000 kg/hr steam generation
  • Life Span 10-15 Years
  • Temperature Ambient to 60C
  • Style Modular Skid-mounted
  • Click to View more
X

Gas Trains Price And Quantity

Gas Trains Product Specifications

  • Natural Gas / LPG
  • Up to 98%
  • Suitable up to 5000 kg/hr steam generation
  • Mild Steel
  • New
  • Stable and Consistent Gas Flow
  • As per burner capacity
  • Regulates, Filters, and Monitors Gas Supply to Equipment
  • 10-15 Years
  • Ambient to 60C
  • Reduced Operating Pressure (as per design)
  • Customized as per boiler & burner requirement
  • Complete Gas Train Assembly
  • 230V/415V (for electro-mechanical actuators)
  • Modular Skid-mounted

Product Description

Gas trains are known for feeding fuel in to a burner by setting up before furnace or boiler. It safely regulates and reduces pressure of incoming gas. Our provided products safely purify the pressure as well. Gas trains have a highly versatility and efficiency. 

Size

Customized

Working Pressure (bar)

4, 7, 10, 12.5,16, 20, 25, 38



Versatile Industry Compatibility

Our gas train assemblies are engineered to meet the exacting demands of diverse sectors, including food, pharmaceutical, chemical, textile, and industrial heating (boilers and furnaces). Each unit is tailored to specific operational parameters, ensuring reliable delivery and regulation of gas supply, regardless of application or facility size.


Integrated Safety and Control Features

The integrated control panel partners seamlessly with flame safety systems to protect equipment and personnel. Advanced safety measures-such as over-pressure cut-off, slam shut valve, and leakage detection-help prevent hazardous incidents. Optional audible-visual alarms provide immediate alerts, ensuring swift response to any irregularity.


Effortless Installation & Customization

Designed with a modular skid-mounted style, our gas trains offer plug & play convenience for both indoor and outdoor set-ups. Customized dimensions ensure adaptability to different boiler and burner setups, and the powder coated or painted finish delivers corrosion resistance, enhancing lifespan and dependable operation.

FAQ's of Gas Trains:


Q: How does the gas train ensure safe operation in industrial environments?

A: The gas train is equipped with a series of safety devices such as over-pressure cut-off, slam shut valve, leakage detector, and optional audible-visual alarms. These systems are integrated with a flame safety panel and, when required, an electronic ignitor to prevent unsafe gas flows, enabling prompt response to anomalies and ensuring a high level of operational safety.

Q: What industries commonly benefit from installing this gas train assembly?

A: Industries such as food processing, pharmaceuticals, chemicals, textiles, and those operating boilers or furnaces can significantly benefit from this gas train. Its ability to reliably regulate, filter, and monitor gas supply ensures stable heating processes and enhanced equipment safety across a range of manufacturing settings.

Q: When is it appropriate to install the gas train indoors versus outdoors?

A: This gas train is suitable for both indoor and outdoor installations, thanks to its weather-resistant, powder coated or painted finish. The decision depends on facility layout, available space, and regulatory requirements. Both environments are supported, ensuring flexibility during facility design or retrofit.

Q: Where in the gas supply line should the gas train assembly be installed?

A: The gas train is typically installed between the main gas supply and end-use equipment (such as boilers or burners). This placement allows the system to efficiently regulate, filter, and monitor the gas flow before it enters the application, providing maximum protection and control.

Q: What is the process for customizing the gas train assembly to fit my equipment?

A: Customization is guided by your boiler or burner's requirements, including gas type, connection size, operating pressure, and capacity (up to 5000 kg/hr steam generation). Our engineering team will recommend the optimal dimensions (L*W*H) and configuration to integrate seamlessly with your existing setup, ensuring efficient installation and operation.

Q: How does using this gas train improve efficiency and reliability?

A: With an ability to maintain stable and consistent gas flow, heat efficiency up to 98%, and reduced pressure operation, this gas train improves fuel utilization and minimizes energy losses. The integrated monitoring and safety systems further guarantee reliable, uninterrupted operation and equipment longevity.